Possible Cause

  • Clogged lint filter
  • Clogged condensate drain or drain hose

Long dry cycle times and fault codes 352 and/or 353 may be present. If fault codes 352 and/or 353 are still present after cleaning the lint filter assembly, the condensate drain hose may be clogged. Follow the repair steps listed below.

  1. Clean the lint filter assembly according to Training Bulletin PTLC24014.
    • Clean BOTH sides of the mesh filter with a soft bristle brush and warm water.
      • If the filter is unable to be cleaned completely, replace the lint filter.
    • Rinse out the foam filter.
    • Reinstall the filter.
    • Run Service Mode Test 15: (HP System Test) to verify fan power is more than 100 watts.
  1. If long dry cycle times, wet loads at end of cycles, or Fault Codes 352 and/or 353 persist after thoroughly cleaning or replacing the lint filter assembly:
    • Verify the condensate drain hose is clogged per condensate drain test.
    • Install Condensate Drain Tube Routing Retrofit Kit, part number WG04F13229.

Applicable Models

PFQ97HSPV0DS PFQ83HSHW0WW PFQ83HSLW0WW PFQ83HSPW0RS PFQ83HSSW0WW

Document Reference Number

PTLC25010